<< Back to Lamps
Lamp Troubleshooting Guide
Troubleshooting Lamps - courtesy of OSRAM
|

|
|
Symptom
Connector base discolored |
|
Fault
Connector base overheated above 230°C due to:
- Faulty electrical connection
- Improper lamp cooling
- Improper operating current |
|
Remedy
Check electrical connections and cooling conditions:
- Tighten or replace
- Check operating current
- Check cooling system (forced or convection) |
|
| |

|
|
Symptom
Cement blackened, cable tarnished |
|
Fault
Connector base overheated; improper lamp cooling |
|
Remedy
Check electrical connections and cooling conditions |
|
| |

|
|
Symptom
Devitrifications and bulb deformation |
|
Fault
Aging of the bulb; Lamp has reached or exceeded the normal life time |
|
Remedy
Lamp change, replacement |
|
| |

|
|
Symptom
Devitrifications and bulb deformation |
|
Fault
Burned-in dirt on the outer bulb surface |
|
Remedy
Before using lamp, clean quartz bulb with a lint-free cloth |
|
| |

|
|
Symptom
Current bar or reflector lamp tarnished |
|
Fault
Improper cooling at front side of reflector |
|
Remedy
Check cooling conditions (forced or convection) |
|
| |
|
 |